The current paper presents the development of a lean premixed prevaporized (LPP) combustion system for a micro gas turbine. A commercial spill return atomizer and a standard fuel oil pump as used in domestic burner applications were specified for the fuel supply system. The relatively large droplet sizes generated by this kind of atomizer system require careful design of the evaporation section of the combustion system. The usage of a LPP combustion concept implies the risk of self ignition and flash back. To avoid both, the knowledge of the ignition delay time and the flame speed of fuel oil are essential for the design of the combustion system. The paper describes the development process of the combustion system and presents experimental results for different geometries and operation conditions.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.