Abstract

This paper presents a new, home-made, GVM (Generating Voltmeter) ion beam energy stabilization system, currently in operation at the Bucharest Tandem Van de Graaff accelerator. The new design combines the signal from the GVM preamplifier with the signal of an original digital reference, in order to obtain an error signal needed by the high-voltage stabilization loop. It is shown that the structure of the employed algorithm provides a high efficiency operation mode for the slow variation of accelerating voltage, with the exception of discharges in the high voltage system. The block structure design, construction features, and tests of this new stabilization system are reported in detail.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.