I developed a beam current transformer (CT) for monitoring the beam of a slow-cycling accelerator. The beam monitor is a new type of CT that measures the average current of a circulating beam using a negative impedance circuit (NIC). Adding an NIC can extend the low-frequency cutoff of a CT down to 0Hz (Ninomiya et al., 2006 [1]). This report presents the detail of our proposed beam-monitoring system. The measurable band width of the CT is 30kHz. The stability of the droop time constant of the square pulse response is ~2%/s. This beam monitor was developed for the synchrotron at the Wakasa–Wan Energy Research Center (WERC) and is currently installed there.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.