Abstract

JAMA-JARI has developed a biofidelic flexible pedestrian leg-form impactor (Flex-PLI 2004) by making several modifications to the Flex-PLI 2003 to improve usability, durability and biofidelity. Biofidelity evaluation for the Flex-PLI 2004 was estimated at the component level (thigh, knee, and leg individually) as well as at the assembly level (thigh-knee-leg complex), using an objective impactor biofidelity evaluation system based on a method developed by Rhule et al. to eliminate any subjective prejudice in an impactor biofidelity evaluation. Applying the biofidelity evaluation system to the Flex-PLI 2004, the average impactor biofidelity rank (IBR) score became 1.22 at the component level and 1.26 at the assembly level. These IBR scores mean that the Flex-PLI 2004 has good biofidelity at the component level as well as at the assembly level. In addition, the average knee joint stiffness of 388 Nm calculated by Kajzer et al. was reanalyzed; it is confirmed that this value was obtained through their miscalculation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.