Abstract

The present study describes a new accurate and precise stability indicating reverse phase HPLC method for quantitative computation of pantoprazole sodium and Aspirin from physical simulated mixture. The proposed chromatographic method employs Hypersil ODS C18 column (250 x 4.6 mm, 5μ) as the stationary phase and combination of methyl alcohol and water in ratio of 70: 30 v/v as the elution medium. Overall separation was carried out at 0.8 ml/minute flow rate and elution was monitored at 254 nm. The proposed system gave well resolved peak of Aspirin and Pantoprazole sodium with elution time of 2.32 and 5.85 minute respectively. Same system was effective in separation of active components and degradation products when the components were subjected to forced degradation as per regulatory guidelines (ICHQ1). Finally, the optimized method was successfully validated as per ICH Q2R1 guidelines and applied for quantitative analysis of both active components in synthetic mixture.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.