Abstract

Life-long adherence to gluten-free diet (GFD) and its assessment is essential for patients with celiac disease (CeD). We have developed and validated a tool for assessing adherence to GFD which can be used by both physicians and dietitians. Phase 1: Development, content validation, and assessment of reliability of tool. Phase 2: Validation of tool against standard dietary evaluation (SDE) (gold standard), immunoglobulin A - anti-tissue transglutaminase antibodies (IgA anti-tTG Ab), and gluten immunogenic peptides in urine. Overall, 380 biopsy-confirmed patients with CeD (derivation cohort: n = 100 [phase 1], n = 210 [phase 2] and independent validation cohort, n = 70) were recruited. Of an initial 90-point questionnaire, 84 items (Celiac Disease: Compliance Assessment Test [CD-CAT.v1]) were retained after content validation and pilot testing. In phase 1, upon administering CD-CAT.v1 on 100 patients, a comprehensive 35-item tool (CD-CAT.v2; α = 0.86) was obtained after removing items with low test-retest reliability and item-rest correlation values. In phase 2, upon administering CD-CAT.v2 on 210 patients, 22 items were removed having low correlation values (R < 0.4) with SDE. Finally, a 13-item tool (CD-CAT.v3; α = 0.84) was obtained with high criterion validity with SDE ( r = 0.806, P < 0.001), moderate convergent validity with celiac disease adherence test ( r = 0.602, P = 0.007), and moderate to weak correlation with urine gluten immunogenic peptides ( r = 0.46, P = 0.001) and IgA anti-tTG Ab ( r = 0.39, P = 0.008), respectively. The final 13-item tool also strongly correlated with SDE ( r = 0.78, P < 0.001) in an independent validation cohort of 70 patients with CeD. Principal component analysis identified 3 relevant subscales with a cumulative variance of 62%. The sensitivity and specificity of CD-CAT.v3 were 80% and 91%, respectively, with an area under curve of 0.905 with SDE. The obtained cutoff score of <19 from the receiver operating characteristic curve was further categorized as 13 = excellent, 14-18 = very good, 19-28 = average, and >28 = poor adherence to GFD. CD-CAT is a new and rapid tool for monitoring dietary adherence to GFD with high sensitivity and specificity, which can be administered by both physicians and dietitians.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.