Abstract

The continuous increase in the use and release of pesticides is worrisome because water contamination can affect health and the environment. This study optimized and validated a multi-residue method in water. The method was developed using the QuEChERS method (Quick, Easy, Cheap, Effective, Rugged, and Safe) followed by ultrahigh- performance liquid chromatography coupled to tandem mass spectrometry (UHPLC-MS/MS). The validation was performed on the matrix (river water) regarding accuracy, precision, linearity, limits of detection (LODs) and limits of quantification (LOQs). LODs were below 3.03 µg L-1and LOQs were from 6.25 to 9.18 µg L-1. The accuracy (recoveries in the range of 80-117%) and for Inter-day precision, the coefficients of variation ranged from 0.35 to 15.71%, and for Intra-day precision were in the range of 0.48 to 7.02%.
 Keywords: multi-residue analysis, pesticide, QuEChERS, water.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.