Abstract
An isocratic high-performance liquid chromatographic method for the determination of testosterone (T) and epitestosterone (ET) in human urine using liquid-liquid or solid-phase extraction (SPE) is developed and validated. The optimum separation is achieved using a Hypersil C(18) column, water-acetonitrile (57:43, v/v) as the mobile phase and UV-absorbance detection at 245 nm. The recoveries obtained for T and ET in liquid-liquid and SPE demonstrate that these procedures are interchangeable. Quantitation limits for T and ET are 8.6 and 5.4 ng/mL using solvent extraction and 7.3 and 5.7 ng/mL using SPE, respectively. The proposed method is used to evaluate the urinary T, ET, and the T/ET ratio for a healthy male population using liquid-liquid extraction, and the T and ET excretion profile for nine healthy men using SPE.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.