Abstract

BackgroundThis study evaluated the performance of a novel fast broad range PCR and sequencing (FBR-PCR/S) assay for the improved diagnosis of invasive fungal disease (IFD) in high-risk patients in a large Canadian healthcare region.MethodsA total of 114 clinical specimens (CS) including bronchoalveolar lavages (BALs) were prospectively tested from 107 patients over a 2-year period. Contrived BALs (n = 33) inoculated with known fungi pathogens were also tested to increase diversity. Patient characteristics, fungal stain and culture results were collected from the laboratory information system. Dual-priming oligonucleotide (DPO) primers targeted to the internal transcribed spacer (ITS) (~ 350 bp) and large subunit (LSU) (~ 550 bp) gene regions were used to perform FBR-PCR/S assays on extracted BALs/CS. The performance of the molecular test was evaluated against standard microbiological methods and clinical review for the presence of IFD.ResultsThe 107 patients were predominantly male (67, 62.6%) with a mean age of 59 years (range = 0–85 years): 74 (69.2%) patients had at least one underlying comorbidity: 19 (34.5%) had confirmed and 12 (21.8%) had probable IFD. Culture recovered 66 fungal isolates from 55 BALs/CS with Candida spp. and Aspergillus spp. being most common. For BALs, the molecular assay vs. standard methods had sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV), and efficiency of 88.5% vs.100%, 100% vs. 61.1%, 100% vs. 88.5%, 61.1% vs. 100%, and 90.2% for both. For other CS, the molecular assay had similar performance to standard methods with sensitivity, specificity, PPV, NPV and efficiency of 66.7%, 87.0%, 66.7%, 87.0% and 81.3% for both methods. Both methods also performed similarly, regardless of whether CS stain/microscopy showed yeast/fungal elements. FBR-PCR/S assays results were reported in ~ 8 h compared to fungal cultures that took between 4 and 6 weeks.ConclusionsRapid molecular testing compared to standard methods have equivalent diagnostic efficiency but improves clinical utility by reporting a rapid species-level identification the same dayshift (~ 8 h).

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.