Abstract
In this study, a modified procedure for quantitative fit testing of disposable masks and respirators using condensation nuclei counting was developed and applied. The procedure permits disposable masks and respirators to be initially tested and retested multiple times after use. Different types of masks and respirators were tested over time and quantitative results were obtained. It was found that after multiple testing that the N95 respirator passed the testing requirements with a fit factor above 100, the KN95 respirator did not perform satisfactorily in the tests, and the disposable masks did not reach fit factors above 4 or 7. The results in this study provided relevant information toward use, reuse, and testing of disposable masks and respirators, particularly relevant during the COVID pandemic when access to N95 respirators was limited.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.