Abstract
<p>The project investigated the potential of building geometry to minimize energy consumption in office buildings. Five distinct geometries were modeled as mid-size office occupancies in the context of Toronto, Ontario, and examined with varied design parameters: window to wall ratio (WWR) and external static shading devices. IES VE software was used to predict the annual energy consumption of the five archetypes for 40 permutations. The outcome of this research showed that the variation of the total energy use from one shape to another was relatively small. WWR appeared to have a stronger impact on the energy pattern of a building than its shape. Overall, the energy performance of the archetypes were observed to conform to their individual building aspect ratios. The findings are thus expected to provide useful guidelines for architects on utilizing building geometry as an energy saving measure in the design of office buildings. </p>
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.