Abstract

Objective To develop a rapid analysis method which is applicable for the monitoring of clinical pharmacy Voriconazole's plasma concentration,and to analyze the monitoring results at the same time.Methods We analyzed plasma from HIV-positive people by high performance liquid chromatography (HPLC),using 5 μ m of Agilent Eclipse XDB-C18 column,mobile phase of 1% isopropyl alcohol:acetonitrile (40∶60),flow rate:1.0 ml/min,wavelength:250 nm,to carry out the recovery rate,linearity and precision tests,and combined with patients' laboratory data,to analyze the significance of blood concentration.Results Within 0.2-19.8 mg · L-1,plasma concentration of Voriconazole standed a good linear relationship(R2=0.9912),recovery rate and precision,showing the specificity of this method.Conclusion Using HPLC to monitor Voriconazole plasma concentration of HIV-positive people is a fast,accurate and efficient analysis method for clinical samples,which can reduce clinical waiting time.Voriconazole plasma concentration monitoring has important clinical value. Key words: Voriconazole; HIV-positive; Plasma concentration monitoring; High performance liquid chromatography

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.