Abstract

The supercritical-fluid extraction of vitamins D2 and D3 with carbon dioxide is reported for the first time. The extraction recovery was enhanced by direct addition of diethyl ether to sample contained in the extraction cell. Separation and detection of the analytes was performed off-line by reversed-phase liquid chromatography with UV-detection. The quantification limit of the method is 4.1 μg for both analytes, with precision, expressed as relative standard deviation, of 3.8 and 6.3% for vitamins D2 and D3, respectively (η=7). The proposed method has been applied to the determination of vitamin D in different pharmaceutical products; recoveries were between 85 and 105%.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.