Abstract
A simple and solvent-minimised sample preparation technique based on hollow fibre-protected liquid-phase microextraction was investigated for the gas chromatography/mass spectrometric analysis of chemical warfare agents in water and slurry samples. The chemical warfare agents included four nerve agents and a blister agent. Parameters such as extraction solvent, salt concentration, stirring speed and extraction time were optimised using spiked deionised water samples. The technique provided a linear range of two orders of magnitude, good repeatability (RSDs < 10%, n = 6), good linearity ( r 2 ≥ 0.995) and limits of detection (LODs) in the range of 0.02–0.09 μg l −1 (S/N = 3) under full scan mode. The optimised technique was also applied to more complex slurry samples and similar precision (RSD < 15%, n = 3) and limits of detection (0.02–0.2 μg l −1, S/N = 3) were obtained.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.