Abstract

A new, sensitive and simple spectrofluorometric method for the determination of thiabendazole (TBZ) residues was studied. TBZ on Sephadex G-15 gel, pH 4.70 acetate buffer, is fixed to give fluorescence. The fluorescence of the gel-TBZ system, packed in a 1-mm quartz cell was measured directly using a solid-surface attachment. The applicable concentration range was 1.5-10.0 ng.mL-1 with a relative standard deviation of 1.4% and a detection limit of 0.1 ng.mL-1. The method was applied to the determination of thiabendazole in natural, waste, sea, and residual waters (98-100% recovery). The method is more sensitive and selective than other methods described in the literature. The presence of other fluorescent pesticides (dichlone, carbaryl, morestan, o-phenylphenol) with similar spectral features (lambda exc and lambda em neighboring to excitation and emission wavelengths of the TBZ) did not cause interference.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.