Abstract

The kinetic parameters of a newly prepared tissue-equivalent, highly sensitive thermoluminescent detector, Li 2 B 4 O 7 : Cu , Ag , P of sintered pellets have been calculated. Thermoluminescence (TL) glow curves of Li 2 B 4 O 7 : Cu , Ag , P samples after β -irradiation showed peaks at about 384 and 446 K with a heating rate of 1 K s - 1 . The kinetic parameters, namely activation energy ( E ) and frequency factor ( s ) associated with the main glow peak (446 K) of Li 2 B 4 O 7 : Cu , Ag , P have been determined using isothermal decay (ID) and peak shape (PS) methods. The activation energies obtained by ID and PS methods are calculated to be 1.12 and 1.13 eV (mean), respectively. The frequency factors obtained by both methods are 7.61 × 10 11 and 3.53 × 10 11 s - 1 (mean), respectively. Results obtained using both methods are compared and discussed.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.