Abstract

Solidification of ionic liquid (SIL) has been applied in microwave-assisted liquid-liquid microextraction method for analyzing Sudan dyes in juice samples. 1-Ethy-3-methylimidazolium hexafluorophosphate ([C2MIM][PF6]) was selected as the extraction solvent due to its relatively high melting point. With the aid of microwave irradiation, the dyes could be easily extracted into ionic liquid phase without dispersive solvent. The solid microdroplet could be easily separated from liquid. Compared with traditional dispersive liquid-liquid microextraction, this method will greatly simplify the collection procedure and shorten the operation time. Several experimental parameters, including the amount of ionic liquid, microwave power and irradiation time, pH of sample solution, and ionic strength, were systematically investigated and optimized. The limits of detection for Sudan I, II, III, and IV were 1.08, 1.30, 1.14, and 1.19 μg/L, respectively. The recoveries of the analytes ranged from 83.42 to 115.56 % and relative standard deviations were lower than 11.53 %, when the present method was applied to the analysis of real samples.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.