Abstract
A sensitive high-performance liquid chromatographic assay has been developed to determine the levels of a new antiretroviral agent, stavudine (2′,3′-didehydro-3′-deoxythymidine, d4T), in human plasma. Didanosine (2′,3′-dideoxyinosine, ddI) was used as the internal standard. The very selective sample pretreatment involved solid-phase extraction using silica gel columns. Chromatography was carried out on a μBondapak phenyl column, using a mobile phase of 0.005 M phosphate buffer (pH 6.8)—methanol (90:10, v/v) and ultraviolet detection at 265 nm. The method has been validated, and stability tests under various conditions have been performed. The detection limit is 10 ng/ml (using 500-μl human plasma samples). The bioanalytical assay has been used in a single pharmacokinetic experiment in a rat to investigate the applicability of the method in vivo.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of Chromatography B: Biomedical Sciences and Applications
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.