Abstract

The humeral heads of whole body cadaveric shoulders underwent fluoroscopic evaluation with the head divided into three zones on both anteroposterior (AP) and axillary views creating nine zones. Five AP and three axillary fluoroscopic images in different rotational positions were assessed for pin penetration. All images were evaluated for pin penetration and the AP view was evaluated for lesser tuberosity location. Pins placed appropriately below the subchondral bone did not appear to penetrate the joint on any fluoroscopic image. Pins placed 2 mm beyond the articular surface were appropriately viewed exiting the head on most views (64%) but falsely appeared within the head on several others (36%). Pins perforating the posterior head were problematic for accurate detection on AP views (missed in 87%), but this was avoided by externally rotating the humerus to 60 degrees. Articular penetration cannot always be appreciated radiographically and special efforts are necessary to avoid this problem including the use of various rotational views as well as the use of appropriate landmarks for orientation such as the lesser tuberosity position.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.