Abstract
Objective To establish a method for detecting phellodendrine hydrochloride content in Qingfeiyihuo pills.Methods Paired ion chromatography was used.Chromatographic column was diamonsil-C18.Mobile phase was a mixture of acetonitrile - 0.1% phosphoric acid( 31:69,V/V )( containing 1.8g sodium dodecyl sulfonate per 100 ml ),with a flow rate of 1.0 mL.min-1.Detection wavelength was 284 nm.Results Phellodendrine hydrochloride had a better linear relation at a concentration of 5.6 - 28.0μg·mL-1 ( r =0.9996 ).The average recovery rate for phellodendrine hydrochloride was 99.4%; precision of the method was 0.71% ( RSD,n =6 ).Conclusions This method can be used in detecting phellodendrine hydrochloride content in Qingfeiyihuo pills. Key words: Qingfeiyihuo pills; Phellodendrine hydrochloride; Paired ion chromatography; Content determination
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.