Abstract
Ion-pair solid-phase extraction was on-line coupled to a chromatographic system with a PLRP-s precolumn and the results were compared with those obtained when C18 sorbents are used. After optimization, the method was used to determine these compounds in two river waters. A sample of 20 ml of river water was preconcentrated with good recovery values for all the compounds studied and detected at 220 nm with detection limits between 0.25 and 0.1 μ1−1. Some of the compounds were provisionally determined by diode-array UV detection.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: International Journal of Environmental Analytical Chemistry
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.