Abstract

This paper describes a simple, rapid, inexpensive method for the preparation of a new biosorbent based on the modification of miswak fibers by NaOH (AT-Miswak-F). The synthesized AT-Miswak-F sorbent was utilized as an efficient sorbent for the extraction and preconcentration of iron group metal ions from various water samples. In this study, it was found that Fe(III), Co(II) and Ni(II) ions were completely extracted (100%) at pH range of 3–7 and flow rate of 0.3–2.0mLmin−1. Also, the sorption capacity of AT-Miswak-F for Fe(III), Co(II) and Ni(II) are 0.54, 0.24 and 0.15mmolg−1, respectively. Equilibrium was best described by Freundlich isotherm model (R2=0.793) and the initial rate constants were 0.077, 0.054 and 0.035mmolg−1min−1, respectively. Under the optimized conditions, the method exhibited a detection limit of 1.4, 2.8 and 2.1ngmL−1 for Fe(III), Co(II) and Ni(II) ions in water samples with relative standard deviations of 2.6% (n=4). The method was successfully applied for the determination of Fe(III), Co(II) and Ni(II) ions in sea, ground and contaminated water samples.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.