Determination of fenofibric acid in saliva and exhaled breath condensate samples using metal- organic frameworks based dispersive micro solid phase extraction coupled to HPLC-PDA.

  • Abstract
  • Literature Map
  • Similar Papers
Abstract
Translate article icon Translate Article Star icon

Determination of fenofibric acid in saliva and exhaled breath condensate samples using metal- organic frameworks based dispersive micro solid phase extraction coupled to HPLC-PDA.

Similar Papers
  • PDF Download Icon
  • Supplementary Content
  • Cite Count Icon 116
  • 10.3390/ijms11114631
Isoprostanes-Biomarkers of Lipid Peroxidation: Their Utility in Evaluating Oxidative Stress and Analysis
  • Nov 17, 2010
  • International Journal of Molecular Sciences
  • Monika Janicka + 3 more

Isoprostanes (IsoPs) are key biomarkers for investigating the role of free radical generation in the pathogenesis of human disorders. To solve IsoPs-related problems with regard to isoprostanes, analytical tools are required. This paper reviews the problems and trends in this field focusing on the methodology for assaying biomarkers in exhaled breath condensate (EBC) samples. A large amount of work has been done in the qualitative and quantitative analysis of IsoPs, but a standardized method has yet to emerge. The methodologies described differ, either in the sample preparation steps or in the detection techniques, or both. Requiring a number of chromatographic steps, the relevant extraction and purification procedures are often critical and time-consuming, and they lead to a substantial loss of target compounds. Recent data show that EBC is a promising non-invasive tool for the evaluation of different diseases. Two main analytical approaches have been adopted for IsoPs measurement: immunological methods and mass spectrometry. The methodologies for the extraction, purification and analysis of IsoPs in EBC samples are presented.

  • Research Article
  • Cite Count Icon 1
  • 10.1088/1752-7163/adf34d
Volatile organic compound and proteomics data from the same exhaled breath condensate sample
  • Aug 4, 2025
  • Journal of Breath Research
  • Shannon E Schrader + 6 more

Obtaining multiple sample types from the same exhaled breath condensate (EBC) sample can reduce the number of samples needed for diagnostics purposes, allowing for sampling to be completed quicker and making it even easier to collect breath from patients. In this study, we performed analysis for volatile organic compounds (VOCs) and proteins from the same EBC sample. Pooled EBC samples were split into two groups: three samples that utilized immersion thin film-solid phase microextraction (TF-SPME) sampling for VOC analysis and three samples that did not undergo TF-SPME sampling (non-TF-SPME). All six EBC samples were analyzed using liquid chromatography with tandem mass spectrometry (LC-MS/MS) for proteomics analysis. VOCs were analyzed via two-dimensional gas chromatography-mass spectrometry (GC x GC-MS). One hundred and eighty-four VOCs were found to be more abundant in EBC samples compared to blank or controls. There was no significant difference in the number of proteins detected in the TF-SPME samples compared to the non-TF-SPME samples and 144 of the 206 total unique proteins detected were found in both sample groups. These results indicate that TF-SPME sampling does not negatively affect the number of proteins that can be detected in EBC. This work is a step towards linking VOC and protein data together to obtain multi-omics breath data from a single breath sample. EBC samples were collected as part of a vaccination clinical trial (NCT05346302).

  • Research Article
  • Cite Count Icon 15
  • 10.1088/1752-7163/ab739b
**The English in this document has been checked by at least two professional editors, both native speakers of English. For a certificate, please see: http://textcheck.com/certificate/ugz1TU.Concordance in molecular genetic analysis of tumour tissue, plasma, and exhaled breath condensate samples from lung cancer patients
  • Apr 15, 2020
  • Journal of Breath Research
  • Aslı Tetik Vardarli + 18 more

Aim. Lung adenocarcinoma is characterized by poor prognosis and short survival rates. Therefore, tools to identify the tumoural molecular structure and guide effective diagnosis and therapy decisions are essential. Surgical biopsies are highly invasive and not conducive for patient follow-up. To better understand disease prognosis, novel non-invasive analytic methods are needed. The aim of the present study is to identify the genetic mutations in formalin-fixed paraffin-embedded (FFPE) tissue, plasma, and exhaled breath condensate (EBC) samples by next-generation sequencing and evaluate their utility in the diagnosis and follow-up of patients with lung adenocarcinoma. Method. FFPE, plasma, and EBC samples were collected from 12 lung adenocarcinoma patients before treatment. DNA was extracted from the specimens using an Invitrogen PureLink Genomic DNA Kit according to the manufacturer’s instructions. Amplicon-based sequencing was performed using Ion AmpliSeq Colon and Lung Cancer Research Panel v2. Results. Genetic alterations were detected in all FFPE, plasma, and EBC specimens. The mutations in PIK3CA, MET, PTEN, SMAD4, and FGFR2 genes were highly correlated in six patients. Somatic and novel mutations detected in tissue and EBC samples were highly correlated in one additional patient. The EGFR p.L858R and KRAS p.G12C driver mutations were found in both the FFPE tissue specimens and the corresponding EBC samples of the lung adenocarcinoma patients. Conclusion. The driver mutations were detected in EBC samples from lung adenocarcinoma patients. The analysis of EBC samples represents a promising non-invasive method to detect mutations in lung cancer and guide diagnosis and follow-up.

  • Research Article
  • Cite Count Icon 36
  • 10.1016/j.ijheh.2016.12.003
The simultaneous detection of trivalent & hexavalent chromium in exhaled breath condensate: A feasibility study comparing workers and controls.
  • Dec 6, 2016
  • International Journal of Hygiene and Environmental Health
  • Elizabeth Leese + 3 more

The simultaneous detection of trivalent & hexavalent chromium in exhaled breath condensate: A feasibility study comparing workers and controls.

  • Research Article
  • Cite Count Icon 29
  • 10.1016/j.jpba.2020.113572
Derivatization and deep eutectic solvent-based air–assisted liquid–liquid microextraction of salbutamol in exhaled breath condensate samples followed by gas chromatography-mass spectrometry
  • Aug 23, 2020
  • Journal of Pharmaceutical and Biomedical Analysis
  • Abolghasem Jouyban + 4 more

Derivatization and deep eutectic solvent-based air–assisted liquid–liquid microextraction of salbutamol in exhaled breath condensate samples followed by gas chromatography-mass spectrometry

  • Research Article
  • Cite Count Icon 7
  • 10.1088/1752-7155/7/4/046007
Detection of pulmonary amylase activity in exhaled breath condensate
  • Nov 28, 2013
  • Journal of Breath Research
  • M Zweifel + 3 more

Amylase activity in exhaled breath condensate (EBC) is usually interpreted as an indication of oropharyngeal contamination despite the fact that amylase can be found in pulmonary excretions. The aim of this study was to recruit and refine an amylase assay in order to detect amylase activity in any EBC sample and to develop a method to identify EBC samples containing amylase of pulmonary origin. EBC was collected from 40 volunteers with an EcoScreen condenser. Amylase assays and methods to discriminate between oropharyngeal and pulmonary proteins were tested and developed using matched EBC and saliva samples. Our refined 2-chloro-4-nitrophenyl-α-D-maltotriosid (CNP-G3) assay was 40-fold more sensitive than the most sensitive commercial assay and allowed detection of amylase activity in 30 µl of EBC. We developed a dot-blot assay which allowed detection of salivary protein in saliva diluted up to 150 000-fold. By plotting amylase activity against staining intensity we identified a few EBC samples with high amylase activity which were aligned with diluted saliva. We believe that EBC samples aligned with diluted saliva contain amylase activity introduced during EBC collection and that all other EBC samples contain amylase activity of pulmonary origin and are basically free of oropharyngeal protein contamination.

  • PDF Download Icon
  • Research Article
  • Cite Count Icon 32
  • 10.1186/1743-422x-8-98
Exhaled breath condensate sampling is not a new method for detection of respiratory viruses
  • Mar 4, 2011
  • Virology Journal
  • Lieselot Houspie + 9 more

BackgroundExhaled breath condensate (EBC) sampling has been considered an inventive and novel method for the isolation of respiratory viruses.MethodsIn our study, 102 volunteers experiencing upper airway infection were recruited over the winter and early spring of 2008/2009 and the first half of the winter of 2009/2010. Ninety-nine EBCs were successfully obtained and screened for 14 commonly circulating respiratory viruses. To investigate the efficiency of virus isolation from EBC, a nasal swab was taken in parallel from a subset of volunteers. The combined use of the ECoVent device with the RTube™ allowed the registration of the exhaled volume and breathing frequency during collection. In this way, the number of exhaled viral particles per liter air or per minute can theoretically be estimated.ResultsViral screening resulted in the detection of 4 different viruses in EBC and/or nasal swabs: Rhinovirus, Human Respiratory Syncytial Virus B, Influenza A and Influenza B. Rhinovirus was detected in 6 EBCs and 1 EBC was Influenza B positive. We report a viral detection rate of 7% for the EBCs, which is much lower than the detection rate of 46.8% observed using nasal swabs.ConclusionAlthough very promising, EBC collection using the RTube™ is not reliable for diagnosis of respiratory infections.

  • Research Article
  • Cite Count Icon 24
  • 10.1039/c8ay02279h
Development of deep eutectic solvent based solidification of organic droplets-liquid phase microextraction; application to determination of some pesticides in farmers saliva and exhaled breath condensate samples
  • Jan 1, 2019
  • Analytical Methods
  • Abolghasem Jouyban + 4 more

The presence of pesticides in exhaled breath condensate and saliva samples of farmers having direct contact with the analytes was monitored using gas chromatography-mass spectrometry.

  • PDF Download Icon
  • Research Article
  • Cite Count Icon 26
  • 10.1128/aem.00515-17
Microbiota in Exhaled Breath Condensate and the Lung.
  • May 31, 2017
  • Applied and Environmental Microbiology
  • Laura Glendinning + 5 more

ABSTRACTThe lung microbiota is commonly sampled using relatively invasive bronchoscopic procedures. Exhaled breath condensate (EBC) collection potentially offers a less invasive alternative for lung microbiota sampling. We compared lung microbiota samples retrieved by protected specimen brushings (PSB) and exhaled breath condensate collection. We also sought to assess whether aerosolized antibiotic treatment would influence the lung microbiota and whether this change could be detected in EBC. EBC was collected from 6 conscious sheep and then from the same anesthetized sheep during mechanical ventilation. Following the latter EBC collection, PSB samples were collected from separate sites within each sheep lung. On the subsequent day, each sheep was then treated with nebulized colistimethate sodium. Two days after nebulization, EBC and PSB samples were again collected. Bacterial DNA was quantified using 16S rRNA gene quantitative PCR. The V2-V3 region of the 16S rRNA gene was amplified by PCR and sequenced using Illumina MiSeq. Quality control and operational taxonomic unit (OTU) clustering were performed with mothur. The EBC samples contained significantly less bacterial DNA than the PSB samples. The EBC samples from anesthetized animals clustered separately by their bacterial community compositions in comparison to the PSB samples, and 37 bacterial OTUs were identified as differentially abundant between the two sample types. Despite only low concentrations of colistin being detected in bronchoalveolar lavage fluid, PSB samples were found to differ by their bacterial compositions before and after colistimethate sodium treatment. Our findings indicate that microbiota in EBC samples and PSB samples are not equivalent.IMPORTANCE Sampling of the lung microbiota usually necessitates performing bronchoscopic procedures that involve a hospital visit for human participants and the use of trained staff. The inconvenience and perceived discomfort of participating in this kind of research may deter healthy volunteers and may not be a safe option for patients with advanced lung disease. This study set out to evaluate a less invasive method for collecting lung microbiota samples by comparing samples taken via protected specimen brushings (PSB) to those taken via exhaled breath condensate (EBC) collection. We found that there was less bacterial DNA in EBC samples compared with that in PSB samples and that there were differences between the bacterial communities in the two sample types. We conclude that while EBC and PSB samples do not produce equivalent microbiota samples, the study of the EBC microbiota may still be of interest.

  • Research Article
  • Cite Count Icon 63
  • 10.4155/bio-2017-0205
Exhaled breath condensate as an alternative sample for drug monitoring.
  • Dec 13, 2017
  • Bioanalysis
  • Maryam Khoubnasabjafari + 2 more

Concerning recent promising findings in the analysis of drugs in EBC and the highly increased demands for therapeutic drug monitoring and related biomedical analyses, finding an appropriate noninvasive sample is a priority.

  • Research Article
  • Cite Count Icon 1
  • 10.1016/j.ejcdt.2017.06.003
MicroRNA7 expression in exhaled breath condensate of smokers with chronic obstructive pulmonary disease: A potential biomarker?
  • Jun 28, 2017
  • Egyptian Journal of Chest Diseases and Tuberculosis
  • Nevine Abd Elfattah + 1 more

MicroRNA7 expression in exhaled breath condensate of smokers with chronic obstructive pulmonary disease: A potential biomarker?

  • Research Article
  • Cite Count Icon 54
  • 10.1378/chest.08-2782
Leukotriene B4 Contributes to Exhaled Breath Condensate and Sputum Neutrophil Chemotaxis in COPD
  • Oct 1, 2009
  • Chest
  • Jean-Louis Corhay + 5 more

Leukotriene B4 Contributes to Exhaled Breath Condensate and Sputum Neutrophil Chemotaxis in COPD

  • Research Article
  • Cite Count Icon 14
  • 10.3389/fgene.2023.1200262
Conversion of specific lncRNAs to biomarkers in exhaled breath condensate samples of patients with advanced stage non-small-cell lung cancer
  • Jun 22, 2023
  • Frontiers in Genetics
  • Aslı Tetik Vardarlı + 7 more

Objectives: Lung cancer (LC) is one of the most prevalent cancers with the highest fatality rate worldwide. Long noncoding RNAs (lncRNAs) are being considered potential new molecular targets for early diagnosis, follow-up, and individual treatment decisions in LC. Therefore, this study evaluated whether lncRNA expression levels obtained from exhaled breath condensate (EBC) samples play a role in the occurrence of metastasis in the diagnosis and follow-up of patients with advanced lung adenocarcinoma (LA).Methods: A total of 40 patients with advanced primary LA and 20 healthy controls participated in the study. EBC samples were collected from patients (during diagnosis and follow-up) and healthy individuals for molecular analysis. Liquid biopsy samples were also randomly obtained from 10 patients with LA and 10 healthy people. The expression of lncRNA genes, such as MALAT1, HOTAIR, PVT1, NEAT1, ANRIL, and SPRY4-IT1 was analyzed using cfRNA extracted from all clinical samples.Results: In the diagnosis and follow-up of patients with LA, lncRNA HOTAIR (5-fold), PVT1 (7.9-fold), and NEAT1 (12.8-fold), PVT1 (6.8-fold), MALAT1 (8.4-fold) expression levels were significantly higher than those in healthy controls, respectively. Additionally, the distinct lncRNA expression profiles identified in EBC samples imply that decreased ANRIL–NEAT1 and increased ANRIL gene expression levels can be used as biomarkers to predict the development of bone and lung metastases, respectively.Conclusion: EBC is an innovative, easily reproducible approach for predicting the development of metastases, molecular diagnosis, and follow-up of LC. EBC has shown potential in elucidating the molecular structure of LC, monitoring changes, and discovering novel biomarkers.

  • PDF Download Icon
  • Research Article
  • Cite Count Icon 7
  • 10.3389/fcimb.2022.1008924
Metabolomic profiling of exhaled breath condensate for the diagnosis of pulmonary aspergillosis
  • Sep 8, 2022
  • Frontiers in Cellular and Infection Microbiology
  • Shuo Wei + 2 more

ObjectiveThis study aims to ascertain the unique metabolic profile of exhaled breath condensate (EBC) samples in pulmonary aspergillosis (PA) patients, and explore their usefulness for the diagnosis of PA.MethodsA total of 133 patients were included in the study, including 66 PA patients (invasive pulmonary aspergillosis, n=3; chronic pulmonary aspergillosis, n=60; allergic bronchopulmonary aspergillosis, n=3) and controls (n=67). Ultra high-performance liquid chromatography coupled with high-resolution mass spectrometry(UHPLC-HRMS) was used to analyze EBC samples. Metabolic profiling of EBC samples that were collected from 22 CPA patients at various times during treatment (before treatment, <1 month, 1–2 months, 2–3 months, 3–6 months, and ≥6 months after treatment initiation) were performed using UHPLC-HRMS. Potential biomarkers were evaluated using cluster analysis, Venn diagram and receiver operating characteristic analysis (ROC).ResultsA total of 47 metabolites of potential interest were detected in the EBC samples. Further investigation showed that Asperpyrone C, Kotanin, Terphenyllin, Terrelumamide B, and Cyclotryprostatin D could be used as a diagnostic biomarker for PA. The classification between metabolic profiling of EBC samples from PA patients and controls was good with a sensitivity of 100%, specificity 89.6% for patients with PA, respectively. Venn diagram analysis of these biomarker candidates displayed three main types of compounds, which could be used for the further discrimination of aspergilloma and chronic cavitary PA. In addition, antifungal treatment had a limited influence on the value of the EBC results.ConclusionsThis metabolomic approach using UHPLC-HRMS could be used as a noninvasive method for the diagnosis of PA.

  • Research Article
  • Cite Count Icon 16
  • 10.1177/25168657231160985
Next Generation Sequencing for miRNA Detection on the Exhaled Breath Condensate: A Pilot Study
  • Jan 1, 2023
  • Epigenetics Insights
  • Roberto Cherchi + 7 more

Introduction:Exhaled breath condensate (EBC) sampling has been suggested as a less-invasive and cost-effective method to detect biological macromolecules, including miRNA. To explore the feasibility of its use as a biomarker of early effects of asbestos exposure, we conducted a preliminary test on male volunteers by comparing the miRNA profile in the EBC and the plasma using 2 different sequencing platforms.Methods:Six male volunteers, all retired and unexposed to dust or fumes, participated in the test. RNA was extracted from 200 μL EBC samples and same-size plasma samples. Sample aliquots were processed in 2 laboratories using 2 different sequencing platforms: a MiSeq Illumina® platform and a more performing HiSeq Illumina® platform.Results:The HiSeq3000® sequencing platform identified twice as many unique molecular indexes (UMI)-validated miRNA as the MiSeq® platform. The Spearman’s correlation coefficient between EBC counts and plasma counts was significant in 5/6 subjects with either platform (MiSeq® = 0.128-0.508, P = .026-<.001; HiSeq® = 0.156-0.412, P = .001-<.001). The intraclass correlation coefficient confirmed the consistency of the miRNA profile over the 6 participants with both biospecimens. Exploring the agreement between the EBC and plasma samples with Bland-Altman plots showed that using the HiSeq3000® platform substantially improved the EBC miRNA detection rate.Conclusion:Our preliminary study confirms that, when using the HiSeq® sequencing platform, EBC sampling is a suitable, non-invasive method to detect the miRNA profile in healthy subjects.

Save Icon
Up Arrow
Open/Close
Notes

Save Important notes in documents

Highlight text to save as a note, or write notes directly

You can also access these Documents in Paperpal, our AI writing tool

Powered by our AI Writing Assistant