Abstract
A method employing gas chromatography for the determination of ethanol in beer has been collaboratively tested by the Analysis Committee of the Institute of Brewing. It was judged that precision values were independent of concentration over the range 0.93 to 6.05% V/V ethanol. Repeatability (r95) and reproducibility (R95) values of 0.061 and 0.136 respectively, were obtained over this range. At a mean level of 9.17% V/V, the r95 and R95 values were 0.154 and 0.284 respectively. This was probably due to dilution errors as the sample had to be diluted to bring it within the linear range of the method. A comparison of the precision values given by the gas chromatographic method, with those obtained in 1991/1992 by 8 laboratories in a major brewing company using 12 sample pairs, for the IOB Recommended Distillation Method, revealed that there is no significant difference between the precision data for the two methods.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.