Abstract
A novel method for determination of diphenylamine (DPA) and its nitrated derivatives, which are considered as characteristic components in smokeless powder and gunshot residues, is described. A tandem mass spectrometric method is established and mass spectrometer parameters optimized for each compound to obtain higher sensitivity. Under optimum conditions, quantitative analysis was carried out. The linear ranges are 5.0-200.0, 2.0-200.0 and 5.0-250.0 ng ml-1 and the detection limits are 1.0, 0.5 and 2.5 ng ml-1 for diphenylamine (DPA), N-NO-diphenylamine (N-NO-DPA) and 4-NO2-diphenylamine (4-NO2-DPA), respectively. Intra-assay and inter-assay precision and accuracy of analysis of these three samples were investigated. Based on the regression lines obtained above, smokeless samples were analyzed. It was found that there are 0.952% DPA, 0.384% N-NO-DPA and 0.128% 4-NO2-DPA in smokeless powder. Recovery tests showed that using cotton swabs, 80.3 +/- 4.9% DPA, 79.6 +/- 3.1% N-NO-DPA and 83.1 +/- 5.4% 4-NO2-DPA could be recovered from human hands.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.