Abstract

In this article, a novel electrochemical sensor based on pristine graphene (PG) is successfully constructed to detect ascorbic acid (AA), dopamine (DA), and uric acid (UA). The PG is obtained by liquid-phase exfoliation of graphite and characterized by transmission electron microscopy and X-ray photoelectron spectroscopy. The sensor based on PG prepared by this method to realize simultaneous determination of AA, DA, and UA is firstly reported. The linear detection ranges for AA, DA, and UA are 9.00–2314μM, 5.00–710μM, and 6.00–1330μM, respectively, with detection limits of 6.45, 2.00, and 4.82μM. This PG based sensor exhibits excellent performance for detection of AA, DA, and UA, which is much better than those electrochemical sensors based on chemical converted graphene.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.