Abstract

Two commercial porcine reproductive and respiratory syndrome virus (PRRSV) antibody ELISA kits (IDEXX and LSI) are currently in extensive use. To determine which kit is more suitable for the evaluation of HP-PRRSV vaccine efficacy, the two kits were used to test 546 serum samples. The agreement between the results was unsatisfactory, with a kappa statistic of 0.681 and a linear correlation coefficient of 0.665. In tests of samples from experimentally vaccinated and PRRSV-negative herds, IDEXX-ELISA identified antibody-positive conversion earlier and showed a higher specificity compared to LSI-ELISA. The serological profile obtained by neutralization testing was closer to that obtained by IDEXX-ELISA than by LSI-ELISA in the late immunization period. The findings reveal that IDEXX-ELISA is the more suitable for the evaluation of antibody response to HP-PRRSV vaccine and for guiding vaccination strategies.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.