Abstract

The profile and normal concentrations of nucleotide metabolites in human saliva and reproducibility of these determinations were analyzed. Samples of human saliva collected from healthy individuals at weekly intervals, were deproteinized and analysed for the content of adenine nucleotides and their metabolites by reversed-phase HPLC. Initial ATP, hypoxanthine and uric acid concentrations were 0.52 +/- 0.15 microM, 1.91 +/- 0.37 microM and 184 +/- 22 microM respectively. A substantial individual variation persisted within 3 weeks of sampling excepted hypoxanthine which showed some unrelated variations. Determination of nucleotides and their catabolites in saliva due to its simplicity and reproducibility, may be of clinical value in diagnosis of local or systemic disorders.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.