Abstract

A method was developed for the determination of the biocide ortho-phenylphenol (biphenyl-2-ol; OPP) in beer, using deuterated OPP as an internal standard. A new liquid-liquid extraction procedure, employing acetonitrile, diethyl ether, and n-pentane, afforded rapid phase separation. The evaporated extract was derivatized with pentafluorobenzyl bromide in a water-acetonitrile mixture that was buffered with potassium carbonate, followed by extraction of the derivative into cyclohexane and analysis by gas chromatography-mass spectrometry in electron ionization mode. The method enables the detection of OPP in 50 mL of beer at concentrations as low as 0.1 microg/L and provides a linear range of quantification of 0.5-40 microg/L. Samples from 61 beers canned over the past 12 years and sold in 27 countries were analyzed for OPP. In 40 of them, the target compound was present at concentrations of 1.2-40 microg/L. Our investigations indicate that the ends of the cans, which contain sealing material presumably treated with OPP, are responsible for this contamination.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.