<span>The main aim of this work is to analyze the input current waveform for a single-phase induction capacitor-run motor (SIMCR) to detect the faults. Internal and external faults were applied to the SIMCR and the current was measured. An armature (broken rotor bar) and bearing faults were applied to the SIMCR. A microcontroller was used to record the motor current signal and MATLAB software was used to analyze it with the different types of fault with varying load operations. Various values of the running capacitor were used to investigate the effect of these values on the wave-current shape. Total harmonic distortion (THD) for the voltage and current was measured. A deep demonstration of the experimental results was also provided for a better understanding of the mechanisms of bearing and armature faults (broken rotor bars) and the vibration was recorded. Spectral and power analyses revealed the difference in total harmonic distortion. The proposed method in this paper can be used in various industrial applications and this technique is quite cheap and helps most of the researchers and very effectual.</span>
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: International Journal of Electrical and Computer Engineering (IJECE)
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.