Abstract

Eccentricity is a common fault in the running of electrical machines. Aimed at the problem, a new approach to detect eccentricity fault is presented by monitoring the slot leakage flux of stator in this paper. In order to measure the slot leakage flux, two placements of search coil in the stator slot are applied. Firstly, the theoretical analysis shows the slot leakage flux contains more information about eccentricity fault than the stator current does. Then the submersible motor as a model, the induced voltages of search coil and the stator currents are obtained by finite element simulation under healthy motor, static, dynamic and mixed eccentricity, respectively. And various analysis and comparisons of simulations are made. The results show that monitoring the slot leakage flux is effective and has more advantages than the motor current signature analysis.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.