Chemometric methods using mid-FTIR spectroscopy were developed in order to reduce the time of study of melamine and cyanuric acid in infant formulas. Chemometric models were constructed using the algorithms Partial Least Squares (PLS1, PLS2) and Principal Component Regression (PCR) in order to correlate the IR signal with the levels of melamine or cyanuric acid in the infant formula samples. Results showed that the best correlations were obtained using PLS1 (R2: 0.9998, SEC: 0.0793, and SEP: 0.5545 for melamine and R2: 0.9997, SEC: 0.1074, and SEP: 0.5021 for cyanuric acid). Also, the SIMCA model was studied to distinguish between adulterated formulas and nonadulterated samples, giving optimum discrimination and good interclass distances between samples. Results showed that chemometric models demonstrated a good predictive ability of melamine and cyanuric acid concentrations in infant formulas, showing that this is a rapid and accurate technique to be used in the identification and quantification of these adulterants in infant formulas.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.