Abstract

A coolant injection into the reactor vessel with depressurization of the reactor coolant system (RCS) has been evaluated as part of the evaluation for a strategy of the severe accident management guidance (SAMG). Two high pressure sequences of a small break loss of coolant accident (LOCA) without safety injection (SI) and a total loss of feedwater (LOFW) accident in Optimized Power Reactor (OPR)1000 have been analyzed by using the SCDAP/RELAP5 computer code. The SCDAP/RELAP5 results have shown that only one train operation of a high pressure safety injection at 30,000 s with indirect RCS depressurization by using one condenser dump valve (CDV) at 6 min after implementation of the SAMG prevents reactor vessel failure for the small break LOCA without SI. In this case, only one train operation of the low pressure safety injection (LPSI) without the high pressure safety injection (HPSI) does not prevent reactor vessel failure. Only one train operation of the HPSI at 20,208 s with direct RCS depressurization by using two SDS valves at 40 min after an initial opening of the safety relief valve (SRV) prevents reactor vessel failure for the total LOFW.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.