Abstract

AbstractIn this study, a steel beam of a Pre-Engineering Building (PEB) constructed in Binh Duong is analyzed and designed according to two American (AISC 360–10) and Vietnamese (TCVN 5575–2012) standards. The authors analyze and design beam structures of a PEB divided into two segments. Software SAP2000 is employed for analyzing the internal forces of the structure. Excel spreadsheet is established for designing steel beams using TCVN 5575–2012, while software SAP2000 is employed directly for designing steel beams using AISC 360–10. The weight of beams is estimated from the cross-section design results of two standards, then the cost of PEB beams is calculated based on their weight. The obtained results of beam design according to AISC 360–10 is more economical than TCVN 5575–2012 up to approximately 36% of the cost based on the mass of steel beams.KeywordsStructural analysisSteel beamStructural designPre-engineering buildingSAP2000AISC 360–10TCVN 5575–2012

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.