Abstract

This research presents the design procedure for liquid – liquid hydrocyclone to separate kerosene – water emulsion. It studies the effects of varying feed flow rate (6, 8, 10, and 12 l/min), inlet kerosene concentration (250, 500, 750, 1000, and 1250 ppm) , and split ratio (0.1, 0.3, 0.5, 0.7, and 0.9) on the outcomes; separation efficiency and pressure drop ratio . This study used factorial experimental design assisted with Minitab program to obtain the optimum operating conditions. It was shown that inlet concentration of 250 ppm, 12 l/min inlet flow rate, and 0.9 split ratio gave 94.78 % as maximum separation efficiency and 0.895 as minimum pressure drop ratio.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.