Abstract

Precision measurement is the premise of precision motion control. When a worktable is operating, the synchronization of multiaxial sampling will directly affect the precision of table position conversion. In this paper, a precise synchrone mechanism for multiaxial laser measurement was proposed. Tests showed that the maximum synchronous sampling time error from 6 laser axes was 0.404 ns. When the table was moving at 1 m/s, the induced maximum displacement conversion error was 0.202 nm, which satisfied the strict nanometer-scale requirement imposed by ultra-precise motion control for position measurement.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.