Abstract
We present a generalized approach for the determination of zone spacing and blaze profile of a plane kinoform lens that provides stigmatic imaging between any two prespecified points on the axis. A unified treatment is provided for kinoform lenses of positive and negative focal lenghts. Some illustrative numerical results demonstrate the feasibility of this approach in practice.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.