Abstract The 1 MVA resistive type single phase AC fault current limiter (FCL) was build and successfully tested by capacitors battery discharge. FCL rated voltage is 3.5 kV, current 250 Arms. The 240 m of HTS tape (type SF12100 by SupePower) was used for FCL production. The FCL consists of 8 bifilar coils each wound onto glass-fiber 70 mm diameter tube and connected in series. The HTS tapes were additionally stabilized with Cu laminated highly resistive foil. During the tests of separate FCL coils at 380 V an excellent limiting performance was observed. Tested FCL coil was switched off after 75 ms, the maximum temperature at the HTS tape was less then 230 K, the recovery time was about 5 s.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.