Abstract

ABSTRACTThe modern commercial and domestic devices are highly sensitive to the variation in system voltage profile. In proposed work, hybrid DG system fed single-phase dynamic voltage restorer (DVR) is proposed for the purpose of mitigation of voltage sags, swells, and interruptions in single-phase distribution system. In the proposed model, switching control strategy of the DG system enables to solve voltage quality problems with minimum requirement of grid energy. The proposed model, during short or long interruption, is capable of meeting load demand and acts as an uninterrupted power source. Also, proportional integral controlled novel boost inverter results in reduced switching losses in comparison to conventional topology, and thus ensuing in saving of significant amount of energy. For the effectiveness of the proposed model of DVR, the simulation results show that it has recovered the voltage sag up to 0.1 pu and swells up to 1.9 pu of pre-sag voltage.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.