Abstract

A new technique for sensorless control of a downhole brushless PM motor connected through a long cable has been described. The cable was assumed to be represented by an RL equivalent circuit. The position estimator structure is simple because its avoids the problems of integration and differentiation of voltage and current signals. The practical implementation of the technique using a DSP system revealed that the noise on the estimated position makes it is necessary to retune the drive, to reduce the response time of its speed control system. Without any special starting procedure, which requires control of the switching of the inverter devices, the motor starting and reversing performance is not satisfactory. Work is in progress to improve the starting and reversing performance of the drive.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.