Abstract

This paper compares a matrix converter (MC) and a DC-voltage link converter with an active front end for a 7.5 kW, 460 V induction motor drive. Part count, semiconductor losses, input filter design, and protection aspects are discussed. It is shown that the matrix converter's semiconductor losses are smaller only at full load operation for the same silicon area in both converters. A 33% reduction of the device current rating of the MC is possible, resulting in comparable thermal device stress. The overall passive component count and rating is only slightly better for the MC.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.