The fast-ion D-alpha diagnostic (FIDA) is employed to detect Dα light emitted by neutralized fast ions during neutral beam injection. A tangentially viewing FIDA has been developed for the HuanLiuqi-2A (HL-2A) tokamak and typically achieves temporal and transverse spatial resolutions of ∼30ms and ∼5cm, respectively. A fast-ion tail on the red shifted wing of the FIDA spectrum is obtained and analyzed with the Monte Carlo code FIDASIM. Good agreement has been presented between the measured and simulated spectra. As the FIDA diagnostic's lines of sight intersect the central axis of neutral beam injection with small angles, the beam emission spectrum is observed with a large Doppler shift. Thus, tangentially viewing FIDA could detect only a small portion of fast ions with an energy of ≈ 20 ∼ 31keV and a pitch angle of ≈ -1 ∼ -0.8. A second FIDA installation with oblique viewing is designed to minimize spectral contaminants.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.