Abstract

In this paper, a 51 level multilevel inverter topology with non modular design is developed, which can be operated in asymmetrical mode with a reduced number of power switches and lesser conduction path. The proposed design has three separated DC sources and eleven active power switches, i.e., ten unidirectional switch and one bidirectional switch. The topology can be used with asymmetrical voltage source configuration to generate fifty one levels. This structure can be cascaded to produce maximum level by a series connection to produce higher voltage levels with less voltage stress on the switches without modifying the topology structure. A detailed Comparison is made with existing topology and recently introduced topologies based on the number of active switches, Separated DC sources, number of gate driver circuits. To prove the presented topology’s superiority, a simple Multicarrier pulse width modulation has been deployed as the switching scheme. Validation on the viability of the proposed topology has been carried out through Matlab/Simulink simulation. KEYWORDS: Non Modular Multilevel Inverter, Reduced Switch.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.