The occupation of TSEE traps in the active surface region of BeO thin film detectors does not depend mainly on the interaction of the primary ionising radiation with the detector material, but is caused by low energy electrons which are generated outside the BeO layer. Therefore the properties of the environment surrounding the detector have a strong influence on the TSEE response. In order to optimise BeO thin film dosemeters for the measurement of Hs(0.07) in beta radiation fields the influence of these properties has been studied. The detectors were covered with foils of Hostaphan and Makrofol. For 90Sr+90Y the influence of scattering from surrounding materials of different composition and geometry has been tested.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.