Abstract

BackgroundDaily delirium assessment using the Confusion Assessment Method for the Intensive Care Unit was recommended for patients in the intensive care unit, yet implementation may be difficult because of lack of simple and standardized data collection schemes which may result in low sensitivities when used by bedside nurses. ObjectiveThis study was to validate the diagnostic accuracy of the intelligent Confusion Assessment Method for the Intensive Care Unit (iCAM-ICU) used by both nurse investigators and bedside nurses in Chinese patients in the intensive care unit. DesignProspective cohort study. SettingA university affiliated tertiary hospital in China. ParticipantsA total of 373 hospitalized patients (181 in phase I and 192 in phase II) in the intensive care units met the inclusion criteria and participated in the study. There were two nursing researchers (phase I) and 24 bedside nurses (phase II) used the iCAM-ICU to assess delirium among patients. MethodsTwo prospective cohort studies were conducted to validate the diagnostic accuracy of iCAM-ICU on delirium screening when it was used by nurse investigators and bedside nurses in the intensive care unit. Using the Diagnostic and Statistical Manual of Mental Disorders as the gold standard, the sensitivity, specificity, predictive values along with the likelihood ratios were determined to estimate the performance of the iCAM-ICU in patients in the intensive care setting. The Kappa consistency test was examined to determine the inter-rater consistency. Subgroup analysis in terms of different age, level of education, severity of illness and cognitive status were also conducted to evaluate potential variations of the iCAM-ICU performance in different patient groups. ResultsA total of 373 patients were included in the validation studies. In comparing with the gold standard, the sensitivities of the iCAM-ICU demonstrated by the two nurse investigators were 95.2 % and 93.7%, while the specificities of the iCAM-ICU were 93.3% and 93.2%. The Kappa consistency between two nurse investigators was 0.96. The sensitivity and specificity of the iCAM-ICU demonstrated by bedside nurses in intensive care patients were 86.7% and 97.7%, respectively. Subgroup analysis also revealed that the sensitivities and specificities in those different subgroups were acceptable, with all statistics being above 80%. ConclusionsThe iCAM-ICU, an information technology enabled delirium screening tool, showed highly acceptable accuracy in detecting delirium in the intensive care units. It can assist bedside nurses to detect delirium reliably and identify potential patients with delirium accurately. Registration numberChiCTR-OCH-13003050.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.