An anastomotic leak is a potentially fatal complication after esophagectomy. This report describes the use of a dehydrated human amnion-chorion membrane (dHACM) placenta allograft patch for reinforcement of an esophageal anastomosis. The anastomotic technique was a modified Orringer procedure through a right thoracotomy (Ivor Lewis procedure). The anastomosis was reinforced with dHACM placenta allograft. Use of the allograft prevented anastomotic leaks and loss of gastrointestinal integrity. Early results are promising.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.