The radome made of C sandwich structure failed after different service time. The failure causes were analyzed by ultrasonic C-scan inspection, fracture surface inspection, section metallographic inspection, bonding strength test, manufacturing process analysis and viscidity testing of film. The results show that: The debonding position of honeycomb composite radome is between honeycomb and outer skin. That is caused by the weak adhesive strength between honeycomb and skin. The main cause of weak adhesion is that the film loses fluidity and viscidity due to the overlong holding time. Weak adhesion is not related to the heating temperature, compressive stress and local honeycomb contamination. The holding time should be controlled to be less than 6h in later manufacture of the radome to keep fluidity and viscidity of film.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.