Abstract

To estimate the RMS value of the DC-link ripple current more accurately, a method is developed considering the reverse recovery of the anti-parallel diode in voltage source inverters (VSIs). In this paper, using the analysis of the inverter DC-link current and anti-parallel diode reverse recovery, calculations are implemented based on the SPWM technique. According to the calculations and simulation and experimental results, it is shown that the calculated ripple current RMS values are higher and closer to the actual values when the diode reverse recovery is considered. In addition, inverter switching frequency also influences this value. Comparing with the experimental results, the error of the DC-link ripple current RMS value estimated by the proposed method vary under different inverter operating conditions and are between 0.1% and 10.5%.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.