Abstract

Performance of gas turbine engine (GTE) deteriorates with structural aging. The availability of operating data from GTE and capability to perform data analysis, provides an opportunity to identify long-term performance deterioration and relate to more difficult to detect structural degradation. In this work, performance analysis of a low power rating and partially loaded industrial GTE was carried out by using a model-free data analytic approach. A performance index (ratio of power generation to fuel consumption) is proposed as the metrics for monitoring the engine performance, and monitor the long-term degradation symptom. A comparative model selection study has been conducted among three multivariable models to select the best model describing long-term performance deterioration of the GTE.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.