Abstract
This study describes a method of diagnosis for multiple IGBT open-circuit faults in vector control induction motor drives. This method combines the wavelet analysis and the support vector machines (SVM). The wavelet analysis is used to extract fault characteristics, and the SVM is used to isolate fault modes. This method can diagnose multiple IGBT open-circuit faults when the motor is at different speeds and loads. The results of Matlab simulation analysis show that this method can effectively carry out the multiple fault diagnosis for IGBT open-circuit faults in vector control induction motor drives.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.